UMC Multiple Entry Power Connection Kit

UMC
Multiple Entry Power Connection Kit
*Use With: SRL, SRP, SRM/E, CWM, SRF, HWM
*3/4” Conduit Hub Opening
*Third-party certifications: UL Listed, CSA, FM, ATEX

Eclipse II Well-Glass EX ZONE 2

Enclosure: Painted aluminium body with glass globe. Silicone rubber gasket. Single stainless steel barrel nut fastener.
Entry: Ceiling mounted: 4 x M20 cable entries
Wall mounted (/WM): 2 x M20 & 2 x M25 cable entries
Pendant mounted (/PE): 1 x M25 pendant cable entry & 4 x M20 cable entries
Termination: 3 core 6mm² max, with looping
Installation: Ceiling, wall, pendant or stanchion mounting
Lampholder: E27 or E40
Lamp Type: HPS, Metal Halide or Mercury Vapour
Control Gear: Internal copper/iron ballast with ignitor and PFC correction capacitors.[br]
Relamping: Access via lamp chamber
Burning Position: Up to 25º off vertical
Ingress Protection: IP66
Electrical Supply:
220, 230, 240V 50Hz (50, 80, 100 & 125W)
220, 230, 240, 254V 50Hz (70, 150, 250 & 400W)

Nexxus Heavy Duty Bulkhead IND

Enclosure: Aluminium LM6 body RAL-9005 black matt fine textured epoxy painted finish with prismatic glass lens, silicone rubber gasket and stainless steel fixings.
Reflector/Geartray: High purity anodised aluminium
Entry: 3 x M20 cable entries
Termination: 3 core 6mm² max conductors with looping or through wiring
Installation: 4 x 7mm clearance holes in body fixing channel
Control Gear: Internal copper/iron ballast with ignitor[br]and PFC correction capacitors (HID lamp models)
Relamping: Access via glass cover secured by 4 stainless steel screws
Ingress Protection: IP66/67
Electrical Supply:
220-240V 50Hz (50W HPS lamp model)
220-254V 50Hz (70W & 80W models)
240V 50Hz (CFL models)
250V Max ac/dc (GLS lamp model)

Arran LED IND

Enclosure: Aluminium alloy with epoxy powder finish
Entry: 2 x M20 cable entries
Termination: 3 core 6mm²
Installation: Stirrup mounting bracket
Lamp Type: LED
Ingress Protection: IP66
Electrical Supply: 120-277V AC 50/60Hz

Eclipse II LED EX ZONE 2

Enclosure: Painted aluminium body with glass globe
Entry: Up to 4 x M20 cable entries
Termination: 3 core 6mm2 max. conductor with looping
Installation: Surface mounted
Control Gear: Electronic Driver
Ingress Protection: IP66
Electrical Supply: 120-254V AC 50/60Hz

Curie Industrial IND

Enclosure: White polyester painted zintec body and frame
Frame colour RAL 9016G Prismatic polycarbonate diffuser
Stainless steel external fasteners
Entry: 4 x 20mm clearance holes, two at one end and two at the other end.
Termination: 4 core 4mm² max. conductors
Installation: Side brackets with adjustable arms (solid ceilings)
Rotating cams (Exposed ‘T’ and Spring ‘T’ ceilings)
There is also a provision for drop rod mounting
Control Gear: High Frequency electronic control gear
Relamping: Via front cover, secured by pan head screws
Ingress Protection: IP44 (Front cover only)
Electrical Supply: 220-240V 50/60Hz AC/DC
Battery: Ni-Cd (6V 4Ah)
Duration: 3 Hours (emergency models)

Nexled LED IND

Enclosure: LM6 aluminium, RAL-9005 black matt fine textured epoxy paint finish with toughened glass and silicone gasket
Reflector/Geartray: Brushed aluminium
Entry: 3 x M20 cable entries
Termination: 4 core 4mm² max. conductors wtih looping
Installation: Surface mounted, 4 mounting holes located outside of seal
Lamp Type: 2 x 1W light emitting diodes (LEDs)
Colour: white
Control Gear: Electronic
Ingress Protection: IP66/67 to EN 60529
Electrical Supply: 220-240C AC/DC
Battery: Ni-Cd (6V)
Duration: 3 hours (emergency models only)
Emergency Output: 100%

800 Series IND

Enclosure: Marine grade 316S31 stainless steel body
(Painted RAL-9005 semi gloss smooth textured)
with toughened glass window, silicone rubber gasket
Reflector/Geartray: Wide beam high purity anodised aluminium
Entry: 2 x M20 cable entries
Termination: 3 core 4mm² max conductors
Installation: Adjustable stirrup bracket
Lampholder: Internal (with remote option using control gear box)
Relamping: Via front cover (c/w safety chains) and quick release clips
Electrical Supply:
220, 230, 240, 254V 50Hz for SON-T & MBI-T lamp models
250V max ac/dc for tungsten halogen lamp models
(Always state V/Hz when ordering)

Nexxus Bulkhead EX ZONE 2

Type of Protection: Ex nR (Restricted Breathing)
Area Classification: Zone 2 areas
ATEX Classification: Group II Category 3 GD
ATEX: Type Examination Certificate BAS99ATEX3012
Coding: Ex II 3 GD Ex nR II (refer to datasheet for T rating and Ambient)
Enclosure: Aluminium LM6 body, RAL-9005 black semi gloss smooth textured finish with prismatic glass lens, silicone rubber gasket and stainless steel fasteners
Reflector/Geartray: High purity anodised aluminium
Entry: 3 x M20 cable entries
Termination: 3 core 6mm² max. conductor wtih looping
or through wiring 16A max. current rating
Installation: Surface mounted, 4 x 7mm clearance holes in body fixing channel
Lampholder: E27 or G24q
Lamp Type: HPS, Metal Halide, Mercury Vapour, Mercury Blended, Compact fluorescent and GLS
Control Gear: Internal copper/iron ballast with ignitor and PFC correction capacitors as specified
Relamping: Access via front cover secured by four stainless steel screws
Burning Position: Universal
Ingress Protection: IP66/67 to EN 60529
Electrical Supply:
220V, 230V, 240V, 254V 50Hz – 70W HPS/Metal Halide
220V, 230V, 240V 50Hz – 80W Mercury Vapour
220V-240V 50Hz – 50W HPS
240V 50Hz – CF
250V max – 200W GLS