Evolution II Asymmetric EX ZONE 1

Type of Protection: Ex d e (Flameproof, Increased Safety), Dust protected enclosure
IIB T* (-ºC < ta < +*ºC)
Ex tD A21 IP67 T*ºC
* – see certificate
Area Classification: Zone 1 and Zone 21 areas
ATEX Classification: Group II Category 2 GD
IECEx: IECEx BAS 05.0045X
ATEX: Type Examination Certificate Baseefa04ATEX0155
Coding: Ex II 2 GD Ex d e IIB (refer to datasheet for T rating and Ambient)
Enclosure: Aluminium alloy LM6 to BS 1490
All fastenings A4 stainless steel
Toughened glass window
Reflector/Geartray: Asymmetric beam, high purity anodised aluminium
Entry: 2 x M20 cable entries
Termination: 3 core 6mm² max.conductor with looping
Installation: Stirrup mounting bracket with aiming quadrant
Lampholder: E40 (R7s for linear Tungsten Halogen)
Lamp Type: HPS, Metal Halide or Tungsten Halogen
Control Gear: Internal copper/iron with PFC correction capacitor and timed ignitor
Relamping: Access via hinged end cover on release of single screw
Burning Position: Universal for HID, +/-45° on horizontal plain for Tungsten Halogen lamps
Ingress Protection: IP66/67 to EN60529
Electrical Supply:
220V, 230V, 240V, 254V 50Hz HPS & Metal Halide
24V-254V Linear Tungsten Halogen
110V-254V Single ended Tungsten Halogen

EFXE SERIES AISI316L PUSH BUTTON STATIONS

Material: Stainless steel AISI-316L
IP Rating: IP66/IP67
Ambient temperature: -50°C to +60°C
Approvals:
IMQ 08 ATEX 028X
GOST R
Marking :
{ex} II 2 GD
Ex-de IIC T(**) Gb / Ex-mb IIC T(**) Gb
Ex-tb IIIC T(**) Db IP66/67
** T6/T85°C, T5/T100°C, T4/T135°C
Standard certificate label: Made by self adhesive UV and corrosion resistant polyester, approved by INERIS Laboratory.
Accessories available upon request:
*Electropolish treatment
*Side gland plates
*Hinges
*Drain/breather valve
*Traffolyte/Stinless steel certificate label
*Internal mounting plate
*Locking facility
*Passing through earth bolt

Sterling II Emergency (GRP) EX ZONE 2

Type of Protection: Ex nA (Non-sparking), Dust protected
T* Tamb= -20ºC to +*ºC
Ex tD A21 IP6X or Ex tD A22 IP6X
(* see product certificate)
Area Classification: Zone 2 areas
Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx SIR.06.0108X
ATEX: Type Examination Certificate Sira 06ATEX4348X
Coding: Ex II 3 GD Ex nA II T4 (refer to datasheet fro T rating and Ambient)
Enclosure: GRP with polycarbonate diffuser and A4 stainless steel retaining clips
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 2 x 20mm diameter holes, one at each end
Termination: 4 core 4mm² max. conductor with through wiring 16A rating
Installation: Two clearance holes for M8 fasteners located on rear of body, sealing washers provided.
Lampholder: G13 (Bi-pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High frequency ballast, electronic charger / invertor
Relamping: Access via front diffuser secured by quick release stainless steel clips
Burning Position: Universal
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220V-254V 50/60Hz
120V Option available
Battery: Ni-Cd battery (6V 4Ah)
Duration: 3 hours
Emergency Output: 18W 32% of one lamp
36W 14% of one lamp
58W 9% of one lamp

Sterling II EX (GRP) ZONE 2

Type of Protection: Ex nA (Non-sparking), Dust protected
T* Tamb= -20ºC to +*ºC
Ex tD A21 IP6X or Ex tD A22 IP6X
(* see product certificate)
Area Classification: Zone 2 and Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx SIR.06.0108X
ATEX: Type Examination Certificate Sira 06ATEX4348X
Coding: Ex II 3 GD Ex nA T4 (refer to datasheet for T rating and Ambient)
Enclosure: GRP with polycarbonate diffuser and A4 stainless steel retaining clips
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 2 x 20mm diameter holes
Termination: 4 core 4mm² max. conductor with through wiring 16A rating
Installation: Two clearance holes for M8 fasteners located on rear of body, sealing washers provided
Lampholder: G13 (Bi-pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High frequency ballast (EOL)
Relamping: Access via diffuser secured by quick release stainless steel clips
Burning Position: Universal
Ingress Protection: IP65 to EN60529
Electrical Supply: 220-254V 50/60Hz (AC/DC)
120V Option available

Protecta n EX ZONE 2

Type of Protection: Ex nA (Non-sparking), Dust protected enclosure II T4 or 150ºC
*-20ºC < Ta < +55ºC
* – see certificate
Area Classification: Zone 2 and Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx BAS 08.0075
ATEX: Type Examination Certificate Baseefa08ATEX0227
Coding: Ex II 3 GD Ex nA (refer to datasheet for T rating and Ambient)
Enclosure: GRP body with polycarbonate cover and brass suspension points
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 4 x M20 cable entries, two at each end
Termination: Quick release terminals – 3 core 4mm² max. conductor with looping 16A rating through wiring (4 core for emergency). 6mm² terminations available, contact sales
Installation: Two M8 tapped brass inserts located on rear of body. (thread depth 12mm)
Lampholder: G13 (Bi-pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High Frequency electronic ballast Emergency
electronic charger/inverter housed in sealed enclosure
Relamping: Quick release diffuser clamp and hinged cover
Burning Position: Universal
Ingress Protection: IP66/67 to EN 60529
Electrical Supply: 220-254V 50/60Hz
Battery: Ni-Cd battery (6V 4Ah)
Duration: 3 hours
Emergency Output: 18W – 32% of one lamp
36W – 14% of one lamp

Curie Elite Recessible EX ZONE 1

Type of Protection: Ex e mb q (Increased safety Encapsulation Powder filling) Dust protected enclosure
Area Classification: Group II Category 2 GD
ATEX Classification: Zone 1 and Zone 21 areas
ATEX: EC Type Examination Certificate BAS02ATEX0117X
Coding: Ex II 2 GD Ex e mb q IIC T4 Tamb 40ºC
Enclosure: White polyester painted zinc coated steel body and aluminium frame. Frame colour RAL 9016G EPDM rubber gasket. Prismatic polycarbonate diffuser. Stainless steel fasteners
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 4 x 20mm holes for cable entries mounted on the top
two at one end and two at the other end
Termination: 3 core 4mm² max. conductor with looping and through wiring facility 16A rating (4 core on emergency)
6mm² terminations available, contact sales
Installation: Fixed side brackets with adjustable arms (Solid ceilings) Rotating cams (Exposed ‘T’ and Spring ‘T’ ceilings)
There is also a provision for drop rod mounting
Lampholder: G13 (Bi pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High frequency (EOL)
Relamping: Access via front cover, secured by pan head slotted screws
Burning Position: Horizontal
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220V-254V 50/60Hz
220V-300V dc (non-emergency only)
Battery: Internal Ni-Cd battery
6V 4 Ah – 18W
6V 7Ah – 36W
Duration: 90 minutes to EN60598-2-22
Emergency Output: 50% of one lamp (18W)
25% of one lamp (36W)
45% HEO Option

Acclaim LED Recessed EX ZONE 1

Type of Protection: Ex e mb q (Increased Safety, Encapsulation, Powder filling)
Area Classification: Zone 1 and 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14
ATEX Classification: Group II Category 2 GD
IECEx: IECEx Certificate of Conformity IECEx CML16.0043X
ATEX: EC Type Examination Certificate CML16ATEX3095X
Coding: Ex eb mb op is q IIC T4 Gb Ex tb IIIC T95°C Db IP65
Enclosure: White polyester painted zintec body and frame. Frame colour RAL 9010. Prismatic Diffuser.
Reflector/Geartray: Aluminium
Entry: 4 x 21mm clearance holes – 2 at each end
Termination: 3 core 4mm² max conductor with looping and 16A rating through wiring (4 core on emergency)
Installation: Fixed side brackets with swing out arms, and provision for drop rod mounting.
Control Gear: Electronic Driver
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220-254V AC, 50/60Hz
Battery: Internal Ni-Cd (6V) (Emergency version only)
Duration: 90 mins (30% output)

RMS 560 EX ZONE 2

Material: AISI304 stainless steel, 0,8mm thickness and transparent part in tempered glass (AISI316L version available upon request)
IP: Rating IP66
Operating Temperature: -20°C to +60°C
Approvals: INERIS 01ATEX0060 (standard)
GOST R (marking upon request, ordering code to be required)
Marking: II 2 GD Ex-de IIC T(**) Ex-tD A21 IP65 T(**) ** T6/T85°C, T5/T100°C, T4/T135°C
Gaskets: Special cross-section tightness gasket, silicon rubber made (closed cell), located in housing channel between body and window frame.
Entries: Body complete of two 21mm Ø through holes (on one side) for cable entry, one complete of metallic plug with M20 locknut and gasket and the other one with temporary plastic plug to prevent dust ingress.
Hardware and screws: AISI304 Stainless steel external hardware and screws
Lamps: RMS series lighting fixtures are suitable for two pins fluorescent lamps G13 socket Philips TL-D or equivalent (lamps excluded)
Ballast: High frequency electronic ballast conforming with EN 60079 – 15 and IEC 60079 – 15
Rated operation voltage (UE): 220-240 V
Frequency: 50-60 Hz
Power factor: > 0,95
Accessories available upon request: Pole mounting kit/Ceiling mounting kit/Suspension mounting kit/Wall mounting kit/3°- 4° through holes opposite side

Operating principles: Available RMS. lighting fixtures for emergency service of one tube:- 90 minutes; guarantees 60’ duration with constant flux (emergency lumen factor 18%) and 30’ with decreasing flux

HEAT TRACE CONTROL

Chromalox Heat Trace Panels are complete control solutions for the most demanding heat trace applications. Our WeatherTRACE and IntelliTRACE lines provide temperature control, monitoring and power management in one package. Choose from 1 to 72 circuit systems for either ambient or line sensing applications in ordinary or hazardous locations. The intelliTRACE line offers advanced features such as sensor mapping, soft start, multiple sensor inputs per circuit and a large touch screen display. Choose the ISC Supervisory Controller to monitor and manage multiple intelliTRACE systems.