Material:
• 1: Enlarger: Polyamide 6
25 % glassfiber reinforced
• 2: Flat Sealing: Neoprene
Temperature range:
-35°C to 90°C
Colour(s)/Designs:
• black
• External thread: Metric
• Internal thread: Metric
• hexagon
Characteristics:
Certificate: LCIE 03 ATEX 0033 U
Type of protection: Ex e
Test standard: EN 60079-0,
EN 60079-7,
EN 61241-0,
EN 61241-1
Device group: II
Category: 2 and 3
Atmosphere: G / D
Zone: 1, 2, 21, 22
Applications:
• for explosion endangered areas
Archives
Flush Push Button
The Harmatex components range features large push button selection, with a choice of momentary or push-push actuation modes; pilot lamps and selector switches, with plastic or metal bezel.
Harmatex range offers unrivalled flexibility with a modular design accomodating up to 6 contacts per operator head.
Material Metal and plastic
IP Rating IP66
Ambient temperature range -20°C to +65°C
Approvals INERIS 02 ATEX 9007U
Marking II 2 GD
Ex d e IIC Gb (contact blocks)
Ex tb IIIC Db
Protecta III LED EX ZONE 1
Type of Protection: Ex e mb q (Increased safety Encapsulation Powder filling)
Area Classification: Zone 1 and Zone 21
ATEX Classification: Group II Category 2 GD
IECEx: IECEx BAS09.0017
ATEX: EC Type Examination Certificate Baseefa04ATEX0220
Coding: Ex II 2 GD Ex e mb q IIC T4 Tamb 55°C
Enclosure: GRP body with polycarbonate cover
Reflector/Geartray: Aluminium
Entry: 4 x M20 cable entries, 2 at each end
Termination: Quick release teminals – 3 core 4mm² max. conductor with looping and 16A rating through wiring (6mm² terminations available, contact sales)
Installation: Two M8 tapped brass inserts located on rear of body
Lamp Type: LED
Control Gear: LED Linear
Ingress Protection: IP66/67 to EN 60529 and deluge tested to DTS-01
Electrical Supply: 220V-254V 50/60Hz
220V – 300V dc
Emergency Output: 90 mins (30% output)
Retrofit LED Gear tray EX ZONE 1
Type of Protection: Ex e mb q (Increased safety Encapsulation Powder filling)
Area Classification: Zone 1 and Zone 21
ATEX Classification: Group II Category 2 GD
IECEx: IECEx ITS 03.0005
ATEX: EC Type Examination Certificate Baseefa04ATEX0220
Coding: Ex II 2 GD Ex e mb q IIC T4 Tamb 55°C
Enclosure: NA
Reflector/Geartray: Aluminium
Entry: NA
Termination: NA
Installation: Fix to existing GRP body – refer to IOM
Control Gear: Electronic Driver
Ingress Protection: IP66/67 to EN 60529 and deluge tested to DTS-01
Electrical Supply: 220V-254V 50/60Hz
220V – 300V dc
Battery: Internal Ni-Cd (6V) (Emergency only)
Duration: 90 mins (30% output)
Acclaim Recessible EX ZONE 1
Type of Protection: Ex e mb q (Increased safety Encapsulation Powder filling)
T4 -20ºC to +45ºC
Ta 95ºC DJP A21 -20ºC to +45ºC
Area Classification: Zone 1 and Zone 21
ATEX Classification: Group II Category 2 GD
IECEx: IECEx ITS 03.0006
ATEX: EC Type Examination Certificate Baseefa04ATEX0286
Enclosure: White polyester painted zinc coated steel body and frame.
Frame colour RAL 9010
Silicone rubber gasket. Clear polycarbonate diffuser
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 4 x 21mm holes, two at one end and two at the other end
Termination: Quick release terminals – 3 core 4mm² max. conductor with looping and through wiring facility (4 core on emergency) 6mm² terminations available, contact sales
Installation: Fixed side brackets with swing out arms, with provision for drop rod mounting
Lampholder: G13 (Bi pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High Frequency (EOL)
Relamping: Via front cover, secured by pan head slotted screws
Burning Position: Horizontal
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220V-254V 50/60Hz
220V-300V dc (non-emergency only)
Battery: Internal Ni-Cd battery
6V 4 Ah – 18W
6V 7Ah – 36W
Duration: 90 minutes to EN60598-2-22
Emergency Output: 50% of one lamp (18W)
25% of one lamp (36W)
45% HEO Option
Evolution Junior Portable EX ZONE 1
Type of Protection: Ex d e (Flameproof Increased Safety)
Area Classification: Zone 1 and Zone 2 areas
ATEX Classification: Group II Category 2 G
IECEx: IECExBAS.11.0021/20
ATEX: EC Type Examination Certificate BAS11ATEX0040
Coding: II 2 G Ex d e IIC (refer to datasheet for T rating and Ambient)
Enclosure: Aluminium alloy LM6 to BS 1490 (AC44100)
All fastenings A4 stainless steel.
Toughened glass window
Reflector/Geartray: Wide beam, high purity anodised aluminium
Entry: 2 x M20 cable entries
Termination: 3 core 6mm² max. conductor with looping
Installation: Stirrup mounting bracket
Lampholder: R7s or E27
Lamp Type: HPS, Metal Halide or Double Ended Linear
Tungsten Halogen
Control Gear: Internal copper/iron with PFC correction capacitor
Relamping: Access via hinged end cover on release of single screw
Burning Position: Universal for HID, +/-45º on horizontal axis for Tungsten Halogen Lamps
Ingress Protection: IP66/67 to EN 60529
Electrical Supply:
220V, 230V, 240V, 254V 50Hz (HID)
24V (AC/DC) – 250V dependant on voltage(Tungsten-Halogen)
Evolution Symmetrical EX ZONE 1
Type of Protection: Ex d e (Flameproof Increased Safety), Dust protected enclosure
IIC T3 or T4 Ta -20ºC to +55ºC
IIB T3 or T4 Ta -50ºC to +55ºC
DIP A21 for dust protected models
Area Classification: Zone 1 and Zone 21 areas
ATEX Classification: Group II Category 2 GD
IECEx: IECEx ITS 03.0002
ATEX: EC Type Examination Certificate BAS98ATEX2373
Coding: Ex II 2 GD Ex d e IIC (refer to datasheet for T rating and Ambient)
Enclosure: Aluminium alloy LM6 to BS 1490
All fastenings A4 stainless steel.
Toughened glass window
Reflector/Geartray: Wide beam, high purity anodised aluminium
Entry: 2 x M20 cable entries
Termination: 3 core 6mm² max. conductor with looping
Installation: Stirrup mounting bracket with aiming quadrant
Lampholder: E40 (R7s for linear Tungsten-Halogen)
Lamp Type: HPS, Metal Halide or Tungsten Halogen
Control Gear: Internal copper/iron with PFC correction capacitor
Relamping: Access via hinged end cover on release of single screw
Burning Position: Universal for HID, +/-45º on horizontal plain for Tungsten-Halogen lamps
Ingress Protection: IP66/67 to EN 60529
Electrical Supply:
220V, 230V, 240V, 254V 50Hz HPS & Metal Halide
24V-254V AC/DC Linear Tungsten Halogen
110V-254V single ended Tungsten Halogen
Evolution II Asymmetric EX ZONE 1
Type of Protection: Ex d e (Flameproof, Increased Safety), Dust protected enclosure
IIB T* (-ºC < ta < +*ºC)
Ex tD A21 IP67 T*ºC
* – see certificate
Area Classification: Zone 1 and Zone 21 areas
ATEX Classification: Group II Category 2 GD
IECEx: IECEx BAS 05.0045X
ATEX: Type Examination Certificate Baseefa04ATEX0155
Coding: Ex II 2 GD Ex d e IIB (refer to datasheet for T rating and Ambient)
Enclosure: Aluminium alloy LM6 to BS 1490
All fastenings A4 stainless steel
Toughened glass window
Reflector/Geartray: Asymmetric beam, high purity anodised aluminium
Entry: 2 x M20 cable entries
Termination: 3 core 6mm² max.conductor with looping
Installation: Stirrup mounting bracket with aiming quadrant
Lampholder: E40 (R7s for linear Tungsten Halogen)
Lamp Type: HPS, Metal Halide or Tungsten Halogen
Control Gear: Internal copper/iron with PFC correction capacitor and timed ignitor
Relamping: Access via hinged end cover on release of single screw
Burning Position: Universal for HID, +/-45° on horizontal plain for Tungsten Halogen lamps
Ingress Protection: IP66/67 to EN60529
Electrical Supply:
220V, 230V, 240V, 254V 50Hz HPS & Metal Halide
24V-254V Linear Tungsten Halogen
110V-254V Single ended Tungsten Halogen
EFXE SERIES AISI316L PUSH BUTTON STATIONS
Material: Stainless steel AISI-316L
IP Rating: IP66/IP67
Ambient temperature: -50°C to +60°C
Approvals:
IMQ 08 ATEX 028X
GOST R
Marking :
{ex} II 2 GD
Ex-de IIC T(**) Gb / Ex-mb IIC T(**) Gb
Ex-tb IIIC T(**) Db IP66/67
** T6/T85°C, T5/T100°C, T4/T135°C
Standard certificate label: Made by self adhesive UV and corrosion resistant polyester, approved by INERIS Laboratory.
Accessories available upon request:
*Electropolish treatment
*Side gland plates
*Hinges
*Drain/breather valve
*Traffolyte/Stinless steel certificate label
*Internal mounting plate
*Locking facility
*Passing through earth bolt