Sterling II LED Linear EX ZONE 2

Type of Protection: Ex nA (Non-sparking), Dust protected enclosure
Area Classification: Zone 2 and Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx CML16.0044X
ATEX: CML16ATEX4101X
Coding: Ex nA IIC T6 Gc Ex tc IIIC T66°C Dc IP64
Enclosure: GRP with prismatic polycarbonate diffuser and stainless steel retaining clips
Reflector/Geartray: Aluminium
Entry: 2 x 20mm diameter clearance holes
Termination: 4 core 4mm² max conductor with looping and through wiring 16A rating
Installation: Two clearance holes for M8 fasteners located on rear of body, sealing washers provided
Ingress Protection: IP64 to EN 60529
Electrical Supply: 220-240V AC, 50/60Hz
Battery: Internal Ni-Cd (6V) (Emergency version only)
Emergency Output: 3 Hours

Sterling II (STST) EX ZONE 2

Type of Protection: Ex nA (Non-sparking), Dust protected enclosure
Area Classification: Zone 2 and Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx SIR06.0108X
ATEX: Type Examination Certificate Sira 06ATEX4348X
Coding: II 3 GD Ex nA II T4 (refer to datasheet for T rating and Ambient)
Enclosure: Marine grade stainless steel body with polycarbonate diffuser and stainless steel retaining clips
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 3 x 20mm diameter holes, Two at one end and one at the other end
Termination: 3 core 4mm² max. conductor with looping and through wiring 16A rating
Installation: Two clearance holes for M8 fasteners located on rear of body, sealing washers provided
Lampholder: G13 (Bi-pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High Frequency ballast housed within sealed enclosure
Relamping: Access via front diffuser secured by quick release stainless steel clips
Burning Position: Universal
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220-254V 50/60Hz (AC/DC) 120V option available (AC only)

Sterling II Emergency (STST) EX ZONE 2

Type of Protection: Ex nA (Non-sparking) Dust protected enclosure
Area Classification: Zone 2 and Zone 22 areas
ATEX Classification: Group II Category 3 GD
IECEx: IECEx SIR06.0108X
ATEX: Type Examination Certificate Sira 06ATEX4348X
Coding: II 3 GD Ex nA II T4 (refer to datasheet for T rating and Ambient)
Enclosure: Marine grade stainless steel body with polycarbonate diffuser and A4 stainless steel retaining clips
Reflector/Geartray: White polyester painted zinc coated steel
Entry: 3 x 20mm diameter holes, two at one end and one at the other end
Termination: 4 core 4mm² max. conductor with looping and through wiring 16A rating
Installation: Two clearance holes for M8 fasteners located on rear of body, sealing washers provided
Lampholder: G13 (Bi-pin)
Lamp Type: T8 tubular fluorescent
Control Gear: High Frequency ballast housed within sealed enclosure,
electronic charger/inverter housed in sealed enclosure, Ni-Cd batteries
Relamping: Access via front diffuser secured by quick release stainless steel clips
Burning Position: Universal
Ingress Protection: IP65 to EN 60529
Electrical Supply: 220-254V 50-60Hz
120V 50/60Hz (available as option)
Battery: Ni-Cd battery (6V 4Ah)
Duration: 3 hours
Emergency Output: 18W 32% of one lamp, 36W 14% of one lamp, 58W 9% of one lamp

SM 15K (15000KW)

Features

Bi-directional power supply with standard 15 kW source and sink
Flexible output with constant power characteristics
Power Regeneration Technology: in sink mode the PSU returns the energy back into the grid
Very low heat dissipation. Efficiency is more than 95%. No need for expensive cooling systems.
Excellent dynamic responses to load changes including all-digital control to adapt regulation to match load type
Designed for long life at full power
Protected against all overload and short circuit conditions

Functionalities

Operation on wide range of 3 phase AC input voltages
Ethernet interface, built-in sequencer and web interface are included
Large user display, menu driven operations
Durable digital encoders for voltage and current adjustment and menu operation
EMC surpasses CE requirements: low emission and high immunity
Low audible noise: temperature controlled cooling fans

Dimensions and Weight
Width = 19″
Height = 3 U
Depth = 591 mm
Weight = 27 kg

SM 6000 (6000W)

Specifications
Three phase input (rated voltage range) : 380 – 480 V AC, Vnom line to line(48-62 Hz)
Power Factor Correction : 0.98 (at 100% load)
Efficiency : up to 90% (at full load)
Output ripple and spikes : from 0.8 mVrms / 10 mVpp
Regulation : from 2.5 mV(0-100% load step)
Recovery time : from 100 μs(50-100% load step)
Programming speed : from 2.7 ms (10-90%),optional from 0.4 ms
Analog programming accuracy : from 0.2%
Output voltage and current stability : 5.10-5 / 10.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20
Dimensions and Weight
Width = 19″
Height = 4 U
Depth = 542 mm
Weight = 27 kg

SM 3300 (3300W)

Specifications
Single and 3-phase input : 180-528 V AC(single or 3-phase 48-62 Hz)derating at low input voltage
Power Factor Correction (PFC) : up to 0.99 at 100% load)
Efficiency : up to 92% (at full load)
Output ripple and spikes : from 3 mVrms / 12 mVpp
Regulation : from 2.5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 1.6 ms (10-90%),optional from 0.2 ms
Output voltage and current stability : 6.10-5 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C
Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20
Dimensions and Weight
Width = 19″
Height = 2 U
Depth = 455 mm
Weight = 15 kg

SM 3000 (3000W)

Specifications
Three phase input : 380 / 400 / 415 V AC,Vnom line to line (48-62 Hz)
Efficiency : up to 90% (at full load)
Output ripple and spikes : from 1.6 mVrms / 8 mVpp
Regulation : from 5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : 7 ms (10-90%),optional from 0.33 ms
Analog programming accuracy : from 0.2%
Stability output voltage and current : 4.10-5 / 10.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = 19″
Height = 3 U
Depth = 416 mm
Weight = 15 kg

SM 1500 (1500W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 (at 100% load)
Efficiency : up to 91% (at full load)
Output ripple and spikes : from 1.8 mVrms / 8 mVpp
Regulation : from 0.5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 3.4 ms (10-90%) optional from 0.2ms
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 6.10-5 / 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = 19″
Height = 2 U
Depth = 365 mm
Weight = 9.9 kg

SM 800 (800W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 (at 100% load)
Efficiency : up to 89% (at full load)
Output ripple and spikes : from 2 mVrms / 8 mVpp
Regulation : from 0.2 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 4 ms (10-90%),optional from 0.2 ms
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 6.10-5 / 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = half 19″
Height = 2 U
Depth = 406 mm
Weight = 5.4 kg