SM 3300 (3300W)

Specifications
Single and 3-phase input : 180-528 V AC(single or 3-phase 48-62 Hz)derating at low input voltage
Power Factor Correction (PFC) : up to 0.99 at 100% load)
Efficiency : up to 92% (at full load)
Output ripple and spikes : from 3 mVrms / 12 mVpp
Regulation : from 2.5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 1.6 ms (10-90%),optional from 0.2 ms
Output voltage and current stability : 6.10-5 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C
Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20
Dimensions and Weight
Width = 19″
Height = 2 U
Depth = 455 mm
Weight = 15 kg

SM 3000 (3000W)

Specifications
Three phase input : 380 / 400 / 415 V AC,Vnom line to line (48-62 Hz)
Efficiency : up to 90% (at full load)
Output ripple and spikes : from 1.6 mVrms / 8 mVpp
Regulation : from 5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : 7 ms (10-90%),optional from 0.33 ms
Analog programming accuracy : from 0.2%
Stability output voltage and current : 4.10-5 / 10.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = 19″
Height = 3 U
Depth = 416 mm
Weight = 15 kg

SM 1500 (1500W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 (at 100% load)
Efficiency : up to 91% (at full load)
Output ripple and spikes : from 1.8 mVrms / 8 mVpp
Regulation : from 0.5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 3.4 ms (10-90%) optional from 0.2ms
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 6.10-5 / 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = 19″
Height = 2 U
Depth = 365 mm
Weight = 9.9 kg

SM 800 (800W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 (at 100% load)
Efficiency : up to 89% (at full load)
Output ripple and spikes : from 2 mVrms / 8 mVpp
Regulation : from 0.2 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 4 ms (10-90%),optional from 0.2 ms
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 6.10-5 / 9.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = half 19″
Height = 2 U
Depth = 406 mm
Weight = 5.4 kg

ES 300 (300W)

Specifications
Single phase input : 92-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 / 0.96 (at 100% load)
Efficiency : up to 86% (at full load)
Output ripple and spikes : 5 mVrms / 15 mVpp
Regulation : from 10 mV (0-100% load step)
Recovery time : from 50 μs (50-100% load step)
Programming speed : from 0.8 ms (10-90%)
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 30.10-5 / 10.10-4
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = half 19″
Height = 66 mm (incl. feet)
Depth = 333 mm
Weight = 3.1 kg

ES 150 (150W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction (PFC) : 0.99 / 0.83 (at 100% load)
Efficiency : up to 84% (at full load)
Output ripple and spikes : 0.5 mVrms / 8 mVpp
Regulation : from 5 mV (0-100% load step)
Recovery time : from 100 μs (50-100% load step)
Programming speed : from 7 ms (10-90%)
Analog programming accuracy : from 0.2%
Stability output voltage andcurrent : 10.10-5 / 10.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = half 19″
Height = 66 mm (incl. feet)
Depth = 202 mm
Weight = 1.7 kg

EST 150 (150W)

Specifications
Single phase input : 90-265 V AC (48-62 Hz)
Active Power Factor Correction(PFC) : 0.99 / 0.83 (at 100% load)
Efficiency : up to 81% (at full load)
Output ripple and spikes : 0.5 mVrms / 8 mVpp
Regulation : from 5 mV (0-100% load step)
Recovery time : 100 μs (50-100% load step)
Tracking accuracy 0.5%
Output voltage and currentstability : 10.10-5 / 10.10-5
MTBF : 500.000 hrs
Operating ambient temperature : -20 to +50 °C

Standards
Power supply standard : EN 61204-3
Generic Emission : EN 61000-6-3 (EN 55022B)
Generic Immunity : EN 61000-6-2
Safety : EN 60950 / EN 61010
Insulation input / output : 3750 Vrms
Protection class : IP20

Dimensions and Weight
Width = half 19”
Height = 146 mm (incl. feet)
Depth = 180 mm
Weight = 3.5 kg

UBC Line Sensing Thermostat Power Connection Kit

NEMA 4X rated junction box designed to connect a single SRL, SRP, SRM/E or CWM cable run to power and control cable output via pipe temperature in non-hazardous areas. This kit provides water-resistant cable entry for one cable, enclosure support, terminal block and a water resistant corrosion resistant wiring enclosure with a 3/4″ opening to accept a conduit hub (CCH- 2 or equal). Stainless steel bulb is 1/4″ diameter x 7-1/4″ long with 3ft capillary. Switch rated for 22 amps SPDT 120-480 volts. Operating temperature range is -40°F to 160°F (-40°C to 71°C). Temperature set point 0° to 400°F (-81°C to 200°C) with 10°F.
* Only Approved for Ordinary Areas.

UAS Ambient-Sensing Thermostat Power Connection Kit

NEMA 4X rated junction box designed to connect a single SRL, SRP, SRM/E or CWM cable run to power and control cable output via ambient air temperature in non-hazardous areas. This kit provides water-resistant cable entry for one cable, enclosure support, terminal block and a water resistant corrosion resistant wiring enclosure with a 3/4″ opening to accept a conduit hub (CCH-2 or equal). Stainless steel sheath probe is 9/16″ diameter x 3″ long. Switch rated for 22 amps SPDT 120-480 volts. Operating temperature range is -40°F to 160°F (-40°C to 71°C). Temperature set point 0° to 225°F (-81°C to 107°C) with 10°F scale divisions.